664 – AL Oil Refill Error
Red alarm.
Associated parameter 1.1480.305
Cause
Corrective action
Summary alarm for automatic oil
replenishment.
u
After initiation of the alarms “HI Oil Refill” and
“HI Lube Oil Level refill” a programmable timeout period starts. The
engine is stopped when this time expires.
665 – AL GET Yellow
Yellow alarm.
Associated parameter 1.4510.993
Cause
Corrective action
An internal summary alarm in
knock control was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
666 – AL IC92x Yellow
Yellow alarm.
Associated parameter 1.4520.993
Cause
Corrective action
An internal summary alarm in the
ignition system was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
667 – AL FSeries Yellow
Yellow alarm.
Associated parameter 1.4530.993
Cause
Corrective action
An internal summary alarm in the
bypass flap was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
668 – AL TecJet Yellow
Yellow alarm.
Associated parameter 1.4540.993
Cause
Corrective action
An internal summary alarm in the
gas control valve was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
669 – AL ProActA Yellow
Yellow alarm.
Associated parameter 1.4550.093
Cause
Corrective action
An internal summary alarm in
restrictor flap A was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.