![MTU 20V4000L32FB Operating Instructions Manual Download Page 91](http://html1.mh-extra.com/html/mtu/20v4000l32fb/20v4000l32fb_operating-instructions-manual_1852707091.webp)
1.4510.199 – Knock Sensor Error A8
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 227).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.200 – Knock Sensor Error A9
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 227).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.201 – Knock Sensor Error A10
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 227).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.202 – Knock Sensor Error B1
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 227).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.203 – Knock Sensor Error B2
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 227).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.204 – Knock Sensor Error B3
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 227).
2. Check sensor (tightening torque, damage), replace as necessary
MS150116/04E 2018-04
| Troubleshooting | 91
TIM-ID: 0000038611 - 006