![MTU 20V4000L32FB Operating Instructions Manual Download Page 188](http://html1.mh-extra.com/html/mtu/20v4000l32fb/20v4000l32fb_operating-instructions-manual_1852707188.webp)
Position
Cylin-
der
1
2
3
4
5
6
7
8
9
10
Overlap TDC in cylinder
A1
Bank A
– –
I –
I X
– X
I –
– X
I –
– –
– X
I X
Bank B
– X
I –
I X
– X
– –
I X
I –
– –
– X
I –
I
Inlet: Valve clearance adjustment of inlet valve is permitted
X
Exhaust: Valve clearance adjustment of exhaust valve is permitted
–
Valve clearance adjustment is not permitted
Table 45: Scheme for valve clearance adjustment
Valve clearance at two crankshaft positions – Check
1.
Check TDC position of piston in cylinder A1:
• If rocker arms on cylinder A1 are unloaded, the piston is in firing TDC.
• If rocker arms on cylinder A1 are loaded, the piston is in overlap TDC.
2.
Check valve clearance with cold engine:
• Inlet valves (long rocker arm) = 0.3 mm
• Exhaust valves (short rocker arm) = 0.5 mm
3.
Check all valve clearances in two crankshaft positions (firing TDC and overlap TDC of cylinder A1) as per
diagram.
4.
Use feeler gauge to determine distance between valve bridge and rocker arm.
5.
If the deviation from the specified value exceeds 0.1 mm, adjust valve clearance.
Valve clearance – Adjustment
1.
Release locknut (1).
2.
Insert feeler gauge (3) between valve bridge
and rocker arm.
3.
Use angular screw driver to set adjusting
screw (2) so that the specified valve clear-
ance is provided.
4.
Feeler gauge (3) must just pass through the
gap.
5.
Use torque wrench to tighten locknut (1) to the specified tightening torque, holding the adjusting screw (2)
to prevent it from turning.
Name
Size
Type
Lubricant
Value/Standard
Locknut
M16
Tightening torque
90 Nm+9 Nm
6.
Replace or rectify adjusting screws and/or locknuts which do not move freely.
7.
Check valve clearance.
Final steps
1.
Remove barring device (→ Page 173).
2.
Install cylinder head cover (→ Page 194).
188 | Valve Drive | MS150116/04E 2018-04
TIM-ID: 0000043600 - 003