![MTU 20V4000L32FB Operating Instructions Manual Download Page 127](http://html1.mh-extra.com/html/mtu/20v4000l32fb/20v4000l32fb_operating-instructions-manual_1852707127.webp)
1.4540.048 – SPI ADC Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
1. Restart TecJet.
2. Replace TecJet.
1.4540.049 – Sense 5V Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
1. Restart TecJet.
2. Replace TecJet.
1.4540.050 – Sense -9V Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
1. Restart TecJet.
2. Replace TecJet.
1.4540.051 – Sense 12V Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
1. Restart TecJet.
2. Replace TecJet.
1.4540.052 – ADC Test Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
1. Restart TecJet.
2. Replace TecJet.
1.4540.053 – CAN Timing Changed
Yellow alarm. Initiated by TecJet.
Cause
Corrective action
Change of CAN baud rate
detected.
1. Check TecJet settings.
2. Check cabling (→ Page 227).
1.4540.054 – Exception Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
1. Restart TecJet.
2. Replace TecJet.
MS150116/04E 2018-04
| Troubleshooting | 127
TIM-ID: 0000038611 - 006