1.4520.605 – MIC5 IPE Prim Short Circuit Cyl 16
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 16 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.606 – MIC5 IPE Prim Short Circuit Cyl 17
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 17 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.607 – MIC5 IPE Prim Short Circuit Cyl 18
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 18 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.608 – MIC5 IPE Prim Short Circuit Cyl 19
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 19 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.609 – MIC5 IPE Prim Short Circuit Cyl 20
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 20 in ignition sequence.
1. Check cabling to ignition coil (→ Page 227).
2. Check ignition coil.
1.4520.610 – MIC5 ISE Secondary Open Cylinder 1
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 1 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.611 – MIC5 ISE Secondary Open Cylinder 2
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 2 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
MS150116/04E 2018-04
| Troubleshooting | 109
TIM-ID: 0000038611 - 006