211 – SD P-Lube Oil
ZKP-Number: 1.8004.563
Signal error, lube oil pressure sensor
Yellow alarm; warning
Cause
Corrective action
Lube-oil pressure sensor faulty.
Short circuit or wire break.
1. Check sensor and wiring (B5), replace as necessary
(→ Page 239).
2. Fault is rectified when engine is restarted (→ Page 52).
3. Contact Service.
212 – SD P-Coolant
ZKP-Number: 1.8004.564
Signal error, coolant pressure sensor
Yellow alarm; warning
Cause
Corrective action
Coolant pressure sensor faulty.
Short circuit or wire break.
1. Check sensor and wiring (B16), replace as necessary
(→ Page 239).
2. Fault is rectified when engine is restarted (→ Page 52).
3. Contact Service.
213 – SD P-Coolant Charge-Air Cooler
ZKP-Number: 1.8004.569
Charge-air cooler coolant pressure sensor faulty
Yellow alarm; warning
Cause
Corrective action
Charge-air cooler coolant
pressure sensor faulty.
Short circuit or wire break.
1. Check sensor and wiring (B43), replace as necessary
(→ Page 239).
2. Fault is rectified when engine is restarted (→ Page 52).
3. Contact Service.
214 – SD P-Crankcase
ZKP-Number: 1.8004.568
Signal error, crankcase pressure sensor
Yellow alarm; warning
Cause
Corrective action
Crankcase pressure sensor
faulty.
Short circuit or wire break.
1. Check sensor and wiring (B50), replace as necessary
(→ Page 239).
2. Fault is rectified when engine is restarted (→ Page 52).
3. Contact Service.