3.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Task
Lube oil system
Check engine oil level (→ Page 192);
Preheat engine oil if required.
Coolant system
Check coolant level (→ Page 208).
Coolant system
Preheat coolant with preheating unit.
Fuel prefilter
Drain (→ Page 165);
Check that suction-side pressure indicated at the fuel prefilter pressure
gauge is within the limit (→ Page 164).
Engine control system
Refer to automation system operating instructions.
ECU
Check plug connections (→ Page 242).
EIM
Check plug connections (→ Page 244).
EMU
Check plug connections (→ Page 243).
MS150067/02E 2014-04