90 – SS Starter Speed Not Reached
ZKP-Number: 2.1090.925
Idling speed not attained
Red alarm; warning
Cause
Corrective action
Various causes possible.
1. Check for additional messages.
2. Contact Service.
91 – SS Release Speed Not Reached
ZKP-Number: 2.1090.924
Runup speed was not attained
Red alarm; warning
Cause
Corrective action
Various causes possible.
1. Check for additional messages.
2. Contact Service.
92 – SS Starter Speed Not Reached
ZKP-Number: 2.1090.923
Starter speed not reached
Red alarm; warning
Cause
Corrective action
Starter rotates too slowly or
does not rotate at all.
1. Check for additional messages.
2. Contact Service.
93 – SS T-Preheat
ZKP-Number: 2.1090.922
Preheating temperature too low (limit value 2)
Red alarm; engine start interlock
Cause
Corrective action
Preheating unit not functioning.
1. Check preheater.
2. Contact Service.
94 – LO T-Preheat
ZKP-Number: 2.1090.921
Preheating temperature too low (limit value 1)
Yellow alarm; warning
Cause
Corrective action
Coolant temperature too low for
engine start because preheating
unit is not functioning.
1. Check preheating unit.
2. Contact Service.
82 | Troubleshooting | MS150067/02E 2014-04
TIM-ID: 0000045495 - 001
Summary of Contents for 16 V 4000 M63L
Page 1: ...Operating Instructions Diesel engine 16 V 4000 M63L MS150067 02E...
Page 3: ...Commissioning Note...
Page 4: ......