508 – AL Incorrect POM ID
ZKP-Number: 1.4500.908
POM sends a different ID number than expected
Yellow alarm; warning
Cause
Corrective action
If alarm 504 occurs in addition,
the resistor in the POM wiring is
missing.
u
Check POM wiring harness.
510 – AL Override applied
ZKP-Number: 2.7002.010
Override was activated
Yellow alarm; warning
Cause
Corrective action
Override suppresses other
alarms.
u
Deactivate Override pushbutton again.
515 – AL Starter Not Engaged
ZKP-Number: 2.1090.926
Yellow alarm - possible start cancelation
Cause
Corrective action
Starter on POM could not be
engaged.
1. Repeat start.
2. Check POM, starter and wiring (→ Page 239).
3. Contact Service.
519 – Oil Level Calibration Error
ZKP-Number: 1.0158.921
Error writing calibration value into flash or SD of level sensor.
Yellow alarm; warning
Cause
Corrective action
Oil level sensor or wiring faulty.
1. Check sensor and wiring, replace as necessary (→ Page 239).
2. Contact Service.
531 – AL Wiring PWM_CM1
ZKP-Number: 1.1044.900
Red alarm
Cause
Corrective action
Wire break or short circuit on
channel PWM_CM1.
u
Check wiring to TecJet throttle, replace TecJet throttle if
necessary.
MS150067/02E 2014-04