![MTU 16 V 4000 M63L Operating Instructions Manual Download Page 58](http://html1.mh-extra.com/html/mtu/16-v-4000-m63l/16-v-4000-m63l_operating-instructions-manual_1852687058.webp)
Simulation of power failure (emergency): SAT
1.
Switch on fuel treatment system (→ Page 59).
2.
Start engine (→ Page 52).
3.
Run engine at idling speed.
4.
Switch off pump (21) at switchgear cabinet (20).
Result:
The engine-mounted fuel delivery pump draws fuel via bypass (2) directly from tank (24).
5.
Check suction pressure at the engine-mounted fuel delivery pump.
Note:
If the suction pressure is within the permissible limits and engine operation is satisfactory.
6.
Operate engine at full load and monitor suction pressure.
Result:
If the suction pressure is within the specified limits, simulation was successful.