Number of cylinders
Engine-mounted heat
exchanger
Remote heat ex-
changer
Number of inlet valves per cylinder
2
2
2
2
Number of exhaust valves per cylinder
2
2
2
2
RAW WATER CIRCUIT (open circuit)
Number of cylinders
Engine-mounted heat
exchanger
Remote heat ex-
changer
Raw water pump: Inlet pressure, min.
L
bar
-0.4
-0.4
--
--
Raw water pump: Inlet pressure, max.
L
bar
1.0
1.0
--
--
Pressure loss in off-engine raw water sys-
tem, max.
L
bar
1.0
1.0
--
--
LUBE-OIL SYSTEM
Number of cylinders
Engine-mounted heat
exchanger
Remote heat ex-
changer
Lube oil operating temperature before en-
gine, from
R
°C
83
85
83
82
Lube-oil operating temperature before en-
gine, to
R
°C
91
93
91
90
Lube-oil operating pressure before engine,
from
R
bar
5.3
5.3
5.3
5.3
Lube oil operating pressure before engine,
to
R
bar
6.3
6.3
6.3
6.3
Lube oil operating pressure (low idle)
(meas. point: before engine)
R
bar
2.5
2.5
2.5
2.5
FUEL SYSTEM
Number of cylinders
Engine-mounted heat
exchanger
Remote heat ex-
changer
Fuel pressure at supply connection to en-
gine, min. (when engine is starting)
L
bar
-0.1
-0.1
-0.1
-0.1
Fuel pressure at supply connection to en-
gine, min. (when engine is running),
L
bar
-0.3
-0.3
-0.3
-0.3
Fuel pressure at supply connection to en-
gine (when engine is starting), max.
L
bar
1.5
1.5
1.5
1.5
Fuel supply flow, max.
A
Liters/
min
GENERAL OPERATING DATA
Number of cylinders
Engine-mounted heat
exchanger
Remote heat ex-
changer
Firing speed, from
R
rpm
80
80
80
80
Firing speed, to
R
rpm
120
120
120
120
46 | Product Summary | MS150067/02E 2014-04
TIM-ID: 0000010796 - 002
Summary of Contents for 16 V 4000 M63L
Page 1: ...Operating Instructions Diesel engine 16 V 4000 M63L MS150067 02E...