365 – AL Stop MV-Wiring Ground
ZKP-Number: 1.8004.561
Injector wiring error
Red alarm - engine shutdown via Protection Module possible
Cause
Corrective action
Short circuit of injector positive
connection to ground of one or
more injectors.
Short circuit of the negative
injector connection or of one or
more injectors to ground.
1. Check wiring (→ Page 239).
2. Engine restart (→ Page 52).
3. Replace wiring harness if necessary (→ Contact Service).
371 – AL Wiring TO 1
ZKP-Number: 1.8004.634
Line disruption
Cause
Corrective action
Short circuit or wire break on
transistor output 1 (TO 1).
1. Check charger valve/wiring, repair as necessary.
2. Replace engine governor.
372 – AL Wiring TO 2
ZKP-Number: 1.8004.635
Line disruption
Cause
Corrective action
Short circuit or wire break on
transistor output 2 (TO 2).
1. Check recirculation valve/wiring, repair as necessary.
2. Replace engine governor.
373 – AL Wiring TO 3
ZKP-Number: 1.8004.636
Line disruption
Cause
Corrective action
Short circuit or wire break on
transistor output 3 (TO 3).
u
-
374 – AL Wiring TO 4
ZKP-Number: 1.8004.637
Line disruption
Cause
Corrective action
Short circuit or wire break on
transistor output 4 (TO 4).
u
-
MS150067/02E 2014-04
| Troubleshooting | 111
TIM-ID: 0000045495 - 001