582 – AL Emergency Stop Failed
Cause
Corrective action
The alarm is issued if the engine
fails to come to a standstill
during a programmable time
after the emergency stop signal
is received.
u
Contact Service.
609 – AL Wiring PWM_CM7
Cause
Corrective action
Cable break or short circuit at
voltage supply of the TRICAN
(B90) or the NOx sensor (B88).
1. Check engine wiring (→ Page 160).
2. Contact Service.
614 – AL L1 P-Fuel Add. Filter Diff.
Cause
Corrective action
The differential pressure above
the fuel additional filter at
sensors B34.2 and B34.3 has
exceeded limit value 1. The
differential pressure is too high.
1. Replace supplementary fuel filter (→ Page 97).
2. Replace fuel filter (→ Page 96).
3. Replace fuel prefilter (→ Page 99).
4. Contact Service.
615 – AL EIL Protection
Cause
Corrective action
Engine number in EIL does not
match the engine number saved
in the ECU
1. Check engine wiring (→ Page 160).
2. Contact Service.
616 – AL EIL Fault
Cause
Corrective action
ECU can not detect EIL.
u
Contact Service.
625 – SD P-Fuel Upstream of Add. Filter
Cause
Corrective action
The HP fuel sensor (B34.3)
before the additional filter
supplies incorrect signal or no
signal.
1. Check engine wiring (→ Page 160).
2. Contact Service.
626 – AL Wiring PWM_CM8
Cause
Corrective action
Disruption or short circuit in
wiring to servomotor of HP
turbine bypass flap M52.
1. Check engine wiring (→ Page 160).
2. Contact Service.
MS150096/03E 2015-04
| Troubleshooting | 61
TIM-ID: 0000029153 - 010