5.8 After stopping the engine – Putting the engine out of
operation
Preconditions
☑
MTU Preservation and Represervation Specifications (A001070/..) are available.
NOTICE
Engine coolant with inadequate freeze protection. Water remaining in the pressure sensors freezes at
temperatures below 0 °C.
Risk of sensor damage!
• Remove pressure sensors and shake off residual water.
After stopping the engine
Item
Measure
Coolant circuit
Drain engine coolant (→ Page 219) and
Drain charge-air coolant (→ Page 230) if
• freezing temperatures are expected, the engine is to remain out of service
for an extended period, but engine coolant has no antifreeze additive.
• the engine room is not heated.
• the coolant is not kept at a suitable temperature.
• the antifreeze concentration is insufficient for the engine-room tempera-
ture.
• the antifreeze concentration is 50% and the engine room temperature is
below -40 °C.
Engine control system
Switch off (see manufacturer's documentation).
Air intake and exhaust sys-
tem
If the equipment is to remain out of service for more than one week, seal the
engine's air and exhaust sides. Otherwise, components carrying air or ex-
haust gas are at risk of corrosion.
If the equipment is to remain out of service for more than one month, pre-
serve the engine (→ MTU Preservation and Represervation Specifications
A001070/..).
74 | Operation | MS15041/03E 2018-08
TIM-ID: 0000002709 - 010
Summary of Contents for 12V4000C*5 series
Page 1: ...Operating Instructions Diesel engine 12V4000Cx5 16V4000Cx5 MS15041 03E...
Page 3: ......
Page 4: ......
Page 46: ...1 B13 Crankskaft speed 44 General Information MS15041 03E 2018 08 TIM ID 0000063565 001...
Page 196: ...1 Bypass flap 194 Exhaust Gas Recirculation MS15041 03E 2018 08 TIM ID 0000063475 002...
Page 264: ...262 Manufacturer s Documentation MS15041 03E 2018 08...
Page 266: ...264 Manufacturer s Documentation MS15041 03E 2018 08 TIM ID 0000098598 001...
Page 267: ...MS15041 03E 2018 08 Manufacturer s Documentation 265 TIM ID 0000098598 001...
Page 268: ...266 Manufacturer s Documentation MS15041 03E 2018 08 TIM ID 0000098598 001...
Page 269: ...MS15041 03E 2018 08 Manufacturer s Documentation 267 TIM ID 0000098598 001...
Page 270: ...268 Manufacturer s Documentation MS15041 03E 2018 08 TIM ID 0000098598 001...
Page 271: ...MS15041 03E 2018 08 Manufacturer s Documentation 269 TIM ID 0000098598 001...
Page 272: ...270 Manufacturer s Documentation MS15041 03E 2018 08 TIM ID 0000098598 001...
Page 273: ...MS15041 03E 2018 08 Manufacturer s Documentation 271 TIM ID 0000098598 001...
Page 274: ...272 Manufacturer s Documentation MS15041 03E 2018 08 TIM ID 0000098598 001...
Page 275: ...MS15041 03E 2018 08 Manufacturer s Documentation 273 TIM ID 0000098598 001...
Page 276: ...274 Manufacturer s Documentation MS15041 03E 2018 08 TIM ID 0000098598 001...
Page 288: ...286 Manufacturer s Documentation MS15041 03E 2018 08 TIM ID 0000083486 002...