5.13 Emergency engine shutdown at LOP (without BlueLine
automation system)
NOTICE
An emergency stop causes extreme stress to the engine plant.
Risk of overheating, damage to components!
• Initiate emergency stop only in emergency situations.
Emergency engine shutdown from LOP
Item
Action
LOP
Open cap of illuminated pushbutton EMERGENCY STOP (→ Page 35).
LOP
Press illuminated pushbutton EMERGENCY STOP.
• Engine is stopped by disconnecting the power supply to the ECU;
• On engines with emergency air-shutoff flaps: flaps close;
• Illuminated pushbutton EMERGENCY STOP flashes. Horn, flashing lamp
etc. are tripped.
After emergency engine shutdown from LOP
Item
Action
LOP
Press illuminated pushbutton ALARM ACKNOWLEDGE (→ Page 35).
• Audible and visual alarm signaling stops.
LOP
Press illuminated pushbutton ALARM ACKNOWLEDGE again.
• Power supply to ECU is provided;
• Alarm has been acknowledged.
Engine
On engines with emergency air-shutoff flaps: open flaps.
• Engine is ready for starting.