Oil filter change with non-rever-
sible filters and stationary en-
gine
1.
Stop engine (→ Page 58) and disable engine
start.
2.
Open screw (1) several rotations and wait un-
til oil filter is empty.
3.
Screw in screw (1) again.
4.
Unscrew oil filter (2) using oil filter wrench.
5.
Clean the sealing face on the adapter.
6.
Check condition of the new sealing ring and
coat it with oil.
7.
Fit SOLAS shield.
8.
Screw on and tighten new engine oil filter by
hand.
9.
Replace further oil filters in the same way.
10.
After each oil change and filter replacement,
bar engine with starting system (→ Page 78).
11.
Check oil level (→ Page 118).
Oil filter change with reversible
filters and stationary engine
1.
Stop engine (→ Page 58) and disable engine
start.
2.
Cut out the filter to be replaced.
A Right filter cut out
B Both filters cut in (operating position)
C Left filter cut out
3.
Wait until oil filter is empty.
4.
Unscrew cut-out oil filter with oil filter
wrench.
5.
Clean the sealing face on the adapter.
6.
Check condition of the new sealing ring and
coat it with oil.
7.
Fit SOLAS shield (→ Page 66).
8.
Screw on and tighten new engine oil filter by
hand.
9.
Replace further oil filters in the same way.
10.
Switch filter to normal position.
11.
After each oil change and filter replacement,
bar engine with starting system (→ Page 78).
12.
Check oil level (→ Page 118).
MS150119/01E 2016-02
| Oil Filtration / Cooling | 121
TIM-ID: 0000064790 - 002