1.4530.009 – Derating Active
Yellow alarm. Initiated by F-series.
Cause
Corrective action
Combined alarm (for details, refer
to the source alarm).
u
Combined alarm (for details, refer to the source alarm).
1.4530.010 – PWM Input High Duty Cycle Error
Yellow alarm. Initiated by F-series.
Cause
Corrective action
F-series setting is incorrect.
u
Check setting.
1.4530.011 – PWM Input Low Duty Cycle Error
Yellow alarm. Initiated by F-series.
Cause
Corrective action
F-series setting is incorrect.
u
Check setting.
1.4530.012 – Analog Input High Error
Yellow alarm. Initiated by F-series.
Cause
Corrective action
F-series setting is incorrect.
u
Check setting.
1.4530.013 – Analog Input Low Error
Yellow alarm. Initiated by F-series.
Cause
Corrective action
F-series setting is incorrect.
u
Check setting.
1.4530.014 – Input Supply Voltage High Error
Yellow alarm. Initiated by F-series.
Cause
Corrective action
Supply voltage has reached
maximum limit value.
1. Check supply voltage.
2. Check cabling.
1.4530.015 – Input Supply Voltage Low Error
Yellow alarm. Initiated by F-series.
Cause
Corrective action
Supply voltage has reached
minimum limit value.
1. Check supply voltage.
2. Check cabling.
86 | Troubleshooting | MS150098/02E 2016-11