1.4520.275 – Odd Energy Level out of Range
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Specified energy level is beyond
the valid range.
u
Adjust value.
1.4520.276 – Even Energy Level out of Range
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Specified energy level is beyond
the valid range.
u
Adjust value.
1.4510.186 – Error Status
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
GET combined alarm. At least one
other GET alarm is pending.
u
Rectify cause of alarm.
1.4510.187 – Combined Error
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Combined alarm (for details, refer
to the source alarm).
u
Combined alarm (for details, refer to the source alarm).
1.4510.188 – Internal Error
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Hardware not ready for operation.
u
Restart knock module.
1.4510.189 – Error Camshaft
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from camshaft sensor
for anti-knock control.
u
Check cabling. Check sensor B 1.3 and replace if necessary.
1.4510.192 – Knock Sensor Error A1
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as necessary.