MTUX/IA-63-00 – Installation Manual
45
Date: 2017/02/17
00
Fig. 5.6.4 (2) Kapton tape in the base
Fig. 5.6.4 (3) Kapton tape in the lid
Within the not metallized connector housing (due to mechanical reasons)
the shielding as well as the frame of the connector itself must be grounded.
This must be done with additional (in cross section wider) strands. They
have to be soldered directly to the device ground (GND pin = power supply
(ie negative) in the plug and to the shielding / the frame.
Fig. 5.6.4 (4): Soldered shieldings and connector to device ground