Fs340_02b_oi_e.docx / Nov-21
Page 42 / 49
Set Directions of Rotation
The direction of rotation must be defined for both, master and slave encoder. Make sure the
Reset is switched on when you do this (the softkey must show “
Reset is ON
”)
•
Move the Master encoder into forward direction (manually or by means of a remote speed
signal to the Master drive). Observe the “
Counter Master
” value shown in the monitor
window on the right. It must count up to positive values and the frequency below must be
positive. Where you find it counts down and the frequency is negative, please click to the
switch “Master Direction” to change th
e counting direction.
•
Move the Slave encoder into forward direction (manually or by enabling the Slave drive
while the Master is moving forward). Observe the “
Counter Slave
” value. It must again
count up to positive values. Where you find it counts down, please click to the switch
“Slave Direction” to change the counting direction.