Fs340_02b_oi_e.docx / Nov-21
Page 24 / 49
F02
Range
Default
F02.009
Synchron Time:
This is an adjustable delay time between reaching the
synchronous speed and switching on the “Ready to cut”
output.
Setting range 1-9999 milliseconds.
Under regular conditions the carriage will be in the
correct cutting position immediately after completion of
the acceleration ramp, and the Sync Time register can
be set to its minimum value of 1 ms.
With mechanically unstable carriage constructions it
may however be applicable to leave a short stabilization
time before activating the cut.
Line Speed
Sync
Time
Output “Ready to Cut”
Carriage Speed
High
Low
1 … 9999
1
F02.010
Tool Width:
Width of the saw blade or cutting tool, scaled in LU
0 …999
0
F02.011
Sampling Time:
Sets the internal digital feed forward control with
respect to dynamics and resolution.
Lower set values result in faster response, but less
accuracy of the feed forward signal. Higher set values
result in better accuracy, but slower response with
sudden speed changes.
Feed forward signals with lower accuracy do not at all
affect speed accuracy of the synchronizing process, but
only might cause slight angular errors.
Depending of the maximum Master encoder frequency,
the subsequent setting can be recommended:
0.001
… 9.980
(seconds)
0.001
fmax
Sampling -Time
1 kHz
0.100 s
3 kHz
0.033 s
10 kHz
0.010 s
30 kHz
0.003 s
≥
100 kHz
0.001 s
F02.012
Wait Time:
Not applicable, leave at default setting.
0.01
… 9.99
(sec.)
9.99