Status message
Description
Output board identification
failed due to unknown error
number
.
The identification of the output board failed due to
unknown error
number
. Characteristic data of the output
board could not be read, they are defective or do not match
the device. Restart the ignition controller. If the error
occurs again after restarting the device, please contact
MOTORTECH.
Output board identification
failed due to unknown hardware.
The identification of the output board failed due to
unknown hardware. Characteristic data of the output board
could not be read, they are defective or do not match the
device. Restart the ignition controller. If the error occurs
again after restarting the device, please contact
MOTORTECH.
Pickup configuration invalid.
The pickup configuration is invalid. This message may
appear during an upgrade/downgrade. Check your
configuration data and the MICT version being used. Then
download the configuration to the device once again.
Power failure detected on output
A
number/
B
number
.
Power supply fault in output board at output
A
number/
B
number
was detected. Restart the ignition
controller. If the error occurs again after restarting the
device, please contact MOTORTECH.
Power output (
x W
) exceeded
error threshold limit (y
W
) at a
supply voltage of
z V
.
The power output (
x W
) exceeded failure threshold (
y W
) at
a supply voltage of
z V
. Increase the supply voltage and
check the energy settings (see
Timing – Schedule A/B –
Energy
on page 106).
Power output (
x W
) exceeded
limit (
y W
) at a supply voltage of
z V
.
The power output (
x W
) exceeded warning threshold limit
(
y W
) for longer than two minutes at a supply voltage of
z V
.
Increase the supply voltage and check the energy settings
(see
Timing – Schedule A/B – Energy
on page 106).
The power output (
x W
) exceeded
permanent limit (y W) at a supply
voltage of
z V
.
The power output (
x W
) exceeded warning threshold limit
(
y W
) for longer than three minutes at a supply voltage of
z V
. Increase the supply voltage and check the energy
settings (see
Timing – Schedule A/B – Energy
on page 106).
PU
number
: Faulty index.
The pickup PU
number
has an error in index. Check the
pickups and the corresponding configuration (see
Engine –
Pickups – General
on page 98). Furthermore, also pay
attention to the instructions in the section entitled
Pickup
Input Errors
Summary of Contents for MIC-Marine