8 Settings via the MICT
98
Rev. 09/2019
–
Max. Power-On Speed
Enter the maximum permitted start speed at which the MIC6 starts sending ignition pulses.
A value of
6000 rpm
is set as the default value: The MIC6 can be activated at the starter
speed and immediately send ignition pulses.
For a value of
0 rpm
the MIC6 can only start sending ignition pulses once it has registered
that the engine is at a standstill.
8.11.6
Engine – Pickups – General
Active pickups
Check when using active pickups that the auxiliary supply voltage is
configured for your application.
Summary of Contents for MIC-Marine