7 Functions
62
Rev. 09/2019
The figure below gives you an overview of the different functions of the timing correction, which
will be explained in more detail in the subsequent sections. Functions that can be
activated/disabled via the MICT are marked by a switch symbol. Depending on the device
version, some functions might not be available.
Per schedule:
Base Timing
Speed Curve
Analog Voltage Input
Analog Current Input
Global:
Ignition Timing Correction
Per cylinder:
Cylinder Individual
Offset
Limited by the
min./max. cylinder
individual offset
Limited by the min./max.
Timing
Summary of Contents for MIC-Marine
Page 1: ...MIC6 Ignition Controller Operating Manual P N 01 10 026 EN Rev 09 2019...
Page 175: ...Rev 09 2019 175...
Page 176: ......