8 Settings via the MICT
132
Rev. 09/2019
–
Category
Type of message (information, warning, error, alarm)
–
Message
Message text; you can find more information on the message text in the following sections.
You have the following options:
–
Automatic scrolling
If this box is checked, the system automatically displays the last list entry until a new event
occurs.
–
Acknowledge Alarms
With this button, you can reset triggered alarms if they are no longer active. An alarm can
only be acknowledged if the checkbox
Permanent – Keep output activated until alarm is
acknowledged
in the alarm configuration is activated.
Date and time of ignition controller
The date and time can be individually configured for each ignition controller
and saved in the device. The device does not adjust automatically for
daylight savings time. Hence, deviations may occur between the device
time and the time on the computer used to access the device.
Correspondingly, the times indicated for the states, messages, and in the
log reflect the time of the ignition controller. The current time of the ignition
controller is shown in the view
Runtime Data – Information
. You can adjust
the time of the ignition controller by entering the desired time in the menu
via
Device -> Set date and time
.
Acknowledging an operational error
While the engine is in standstill, there are the following options for
acknowledging operational errors:
–
via
Device -> Send command -> Acknowledge operational error
in the
MICT
–
Restart / Reset
–
Hold button
PB
on the controller longer than three seconds
Acknowledging warnings
You can acknowledge a warning by briefly pressing the pushbutton
PB
on
the controller.