4 Product Description
Rev. 09/2019
31
The status LED flashes red:
–
Critical error/ Assertion
fast flashing red/off 100 ms
–
Operating error – General/ System error
slow flashing red/off 500 ms
–
Bootloader – Faulty firmware
Flashing one time red 2,000 ms on, 250 ms off
–
Operational error – Pickup
2 flashes red/off 250 ms, 750 ms off
–
Operational error – Overspeed
4 flashes red/off 250 ms, 750 ms off
–
Operational error – Insufficient supply voltage
5 flashes red/off 250 ms, 750 ms off
The status LED flashes orange:
–
Self test
Flashing one time orange 250 ms on, 750 ms off