4. Service Procedures - Machine Adjustments and Calibration
60
Morgana DocuMaster MFC - Service Manual
4.5
Machine Adjustments and Calibration
4.5.1
Adjust the Vacuum Pump Pressure
The vacuum pump pressure is factory set to a maximum -125mBar (3.7"Hg). This
setting should never need to be adjusted.
4.5.2
Adjust the Main Drive Belt Tension
It is important that the main drive belt is tensioned correctly to prevent belt slip or
overload of the drive motor.
There must be 10 - 20mm of
deflection in the centre of the
drive belt here.
Belt Tensioner Pulley
Figure 4.24
Correct Main Drive Belt Tension
Belt Tensioner Locking
Nut and Adjustment Slot
Figure 4.25
Main Drive Belt Tensioner Locking Nut
The correct drive belt tension is:
10mm - 12mm of deflection at the centre of the drive belt.
Tools:
•
Allen Key: 3mm
•
Spanner: 10mm.
Before you start:
•
Remove the LH top side cover (See Section 4.2.6).
Summary of Contents for DocuMaster MFC
Page 8: ...CONTENTS vi Morgana DocuMaster MFC Service Manual ...
Page 9: ...Morgana DocuMaster MFC Service Manual 1 1 SECTION 1 Introduction ...
Page 27: ...Morgana DocuMaster MFC Service Manual 19 2 SECTION 2 Error Conditions ...
Page 43: ...Morgana DocuMaster MFC Service Manual 35 3 SECTION 3 Output Quality Problems ...
Page 46: ...3 Output Quality Problems Crease Quality 38 Morgana DocuMaster MFC Service Manual ...
Page 47: ...Morgana DocuMaster MFC Service Manual 39 4 SECTION 4 Service Procedures ...
Page 196: ...4 Service Procedures The MFC Maintenance Schedule 188 Morgana DocuMaster MFC Service Manual ...
Page 197: ...Morgana DocuMaster MFC Service Manual 189 5 SECTION 5 Parts Lists ...
Page 199: ...Morgana DocuMaster MFC Service Manual 191 6 SECTION 6 General Procedures ...
Page 221: ...Morgana DocuMaster MFC Service Manual 213 7 SECTION 7 Electrical and Control System ...
Page 259: ...Morgana DocuMaster MFC Service Manual 251 8 SECTION 8 Installation Manual ...
Page 266: ...8 Installation Manual Install the MFC 258 Morgana DocuMaster MFC Service Manual ...
Page 267: ......