7. Electrical and Control System - Low Voltage Transformer Tappings
216
Morgana DocuMaster MFC - Service Manual
207V – 216V Input = (187V – 220V range) = 200V Tap
•
The measured voltage = 216V
•
The usual local input voltage = 210V – 254V
•
Use transformer tap position = 200V
7.2.2
Low Voltage Transformer Output
The, low voltage AC output cable from the low voltage transformer, connects to PL1 on
the interface PCB in the DRV module. The table that follows shows the nominal output
voltages of the transformer.
Low Voltage Output
Wire Pair
Voltage (VAC)
White
9.0V
Orange
21.0V
Summary of Contents for DocuMaster MFC
Page 8: ...CONTENTS vi Morgana DocuMaster MFC Service Manual ...
Page 9: ...Morgana DocuMaster MFC Service Manual 1 1 SECTION 1 Introduction ...
Page 27: ...Morgana DocuMaster MFC Service Manual 19 2 SECTION 2 Error Conditions ...
Page 43: ...Morgana DocuMaster MFC Service Manual 35 3 SECTION 3 Output Quality Problems ...
Page 46: ...3 Output Quality Problems Crease Quality 38 Morgana DocuMaster MFC Service Manual ...
Page 47: ...Morgana DocuMaster MFC Service Manual 39 4 SECTION 4 Service Procedures ...
Page 196: ...4 Service Procedures The MFC Maintenance Schedule 188 Morgana DocuMaster MFC Service Manual ...
Page 197: ...Morgana DocuMaster MFC Service Manual 189 5 SECTION 5 Parts Lists ...
Page 199: ...Morgana DocuMaster MFC Service Manual 191 6 SECTION 6 General Procedures ...
Page 221: ...Morgana DocuMaster MFC Service Manual 213 7 SECTION 7 Electrical and Control System ...
Page 259: ...Morgana DocuMaster MFC Service Manual 251 8 SECTION 8 Installation Manual ...
Page 266: ...8 Installation Manual Install the MFC 258 Morgana DocuMaster MFC Service Manual ...
Page 267: ......