Flow Sensor
Cable Connector
Morgana DocuMaster MFC - Service Manual
169
4. Service Procedures - Replace Components - Gathering Area
4
Figure 4.180
Gathering Area Flow Sensor
Sensor Mounting Clip
Locating Peg
Figure 4.181
The Flow Sensor
Tools:
•
Allen Key: 3mm
•
Screwdriver: Small Flat Blade
•
Pliers: Small Long Nose.
Before you start:
•
Remove the gathering area centre guard (See Section 4.2.11).
(1)
Press the latch down on the flow sensor cable connector and pull the connector
away from the flow switch.
(2)
Press the latches of the sensor mounting clip together and pull the sensor away
from the mounting bracket.
(3)
Push the replacement sensor into place.
Summary of Contents for DocuMaster MFC
Page 8: ...CONTENTS vi Morgana DocuMaster MFC Service Manual ...
Page 9: ...Morgana DocuMaster MFC Service Manual 1 1 SECTION 1 Introduction ...
Page 27: ...Morgana DocuMaster MFC Service Manual 19 2 SECTION 2 Error Conditions ...
Page 43: ...Morgana DocuMaster MFC Service Manual 35 3 SECTION 3 Output Quality Problems ...
Page 46: ...3 Output Quality Problems Crease Quality 38 Morgana DocuMaster MFC Service Manual ...
Page 47: ...Morgana DocuMaster MFC Service Manual 39 4 SECTION 4 Service Procedures ...
Page 196: ...4 Service Procedures The MFC Maintenance Schedule 188 Morgana DocuMaster MFC Service Manual ...
Page 197: ...Morgana DocuMaster MFC Service Manual 189 5 SECTION 5 Parts Lists ...
Page 199: ...Morgana DocuMaster MFC Service Manual 191 6 SECTION 6 General Procedures ...
Page 221: ...Morgana DocuMaster MFC Service Manual 213 7 SECTION 7 Electrical and Control System ...
Page 259: ...Morgana DocuMaster MFC Service Manual 251 8 SECTION 8 Installation Manual ...
Page 266: ...8 Installation Manual Install the MFC 258 Morgana DocuMaster MFC Service Manual ...
Page 267: ......