6. General Procedures - The Diagnostic Tools Pages
206
Morgana DocuMaster MFC - Service Manual
1
GUi CPU replied with a NAK
2
Time-out, GUI CPU failed to reply fully.
3
UART fifo overflow in MFC
4
GUI CPU reply too long (Message buffer overflow)
5
GUI CPU failed to respond to ! K8 command
6
UART framing error in MFC
10
Data string returned by GUI CPU was malformed
11
Check sum on data string bad
20
Invalid code for MODE (M field)
21
Invalid length (L field)
22
Invalid fold distance (F field)
23
Invalid Offset (O field)
24
Invalid Skew (S field)
25
Invalid Hinge on/off (H field)
26
Invalid Hinge distance (D field)
27
Invalid SIZE
28
Invalid INSERT
29
INFO
30
WIDTH
31
NSHEETS
‘Y’ Manually Set the Solenoid Outputs
Not used.
Yn
n = 0 Both outputs OFF.
n = 1 Solenoid 1 ON; Solenoid 2 OFF.
n = 2 Solenoid 1 OFF; Solenoid 2 ON.
n = 3 Both solenoids OFF.
Summary of Contents for DocuMaster MFC
Page 8: ...CONTENTS vi Morgana DocuMaster MFC Service Manual ...
Page 9: ...Morgana DocuMaster MFC Service Manual 1 1 SECTION 1 Introduction ...
Page 27: ...Morgana DocuMaster MFC Service Manual 19 2 SECTION 2 Error Conditions ...
Page 43: ...Morgana DocuMaster MFC Service Manual 35 3 SECTION 3 Output Quality Problems ...
Page 46: ...3 Output Quality Problems Crease Quality 38 Morgana DocuMaster MFC Service Manual ...
Page 47: ...Morgana DocuMaster MFC Service Manual 39 4 SECTION 4 Service Procedures ...
Page 196: ...4 Service Procedures The MFC Maintenance Schedule 188 Morgana DocuMaster MFC Service Manual ...
Page 197: ...Morgana DocuMaster MFC Service Manual 189 5 SECTION 5 Parts Lists ...
Page 199: ...Morgana DocuMaster MFC Service Manual 191 6 SECTION 6 General Procedures ...
Page 221: ...Morgana DocuMaster MFC Service Manual 213 7 SECTION 7 Electrical and Control System ...
Page 259: ...Morgana DocuMaster MFC Service Manual 251 8 SECTION 8 Installation Manual ...
Page 266: ...8 Installation Manual Install the MFC 258 Morgana DocuMaster MFC Service Manual ...
Page 267: ......