Programmable Multi-Axis Servo Drive Power Supply Unit Operation Manual
ID no.: CA97556-001 Date: 03/2015
moog
58
Commissioning
The following functions and displays are available:
y
Display of device state (see section 5.1, p. 64) The device state is displayed
when the control supply is switched on. If no input is made via the keypad for
60 seconds, the display switches back to the device state.
y
Display of device error state (see section 5.1.1, p. 64) If a device error occurs the
display immediately switches to show the error code.
y
Parameter setting (display "PA") (see section 4.4.3, p. 60) Reset device
parameters to factory defaults and data set handling by way of the MMC card
y
Ethernet IP address setting (display "IP") (see section 4.4.4, p. 61) Set
Ethernet IP address and subnet mask
y
Field bus settings (display "Fb") (see section 4.4.5, p. 62) Set fieldbus address
for example
y
Firmware update with MMC card (see section 4.4.6, p. 63)
4.4
Integrated operator control unit and MMC
card
The built-in operator control unit permits diagnosis of the servo drive. In addition, use
of the MMC card aids serial commissioning without a PC. The operator control unit
comprises the following elements, all located on the front of the device:
y
2-digit 7-segment display (D1, D2)
y
Two pushbuttons (T1, T2)
y
MMC slot (X1)MMCplus cards of type SC-MMC128 (128 MB memory capacity
and 3.3 V supply voltage) can be inserted. For more details see Programmable
Multi-Axis Servo Drive System (MSD) Ordering Catalog).
D1
D2
T2
T1
X1
Figure 4.7 Integrated operator control unit