A.14 Measures to attain UL approbation
(UL 508C) size 6A
1.
Maximum temperature of ambient air: +40 °C (+104 °F) complete.
2.
The devices are usable in systems with a maximum current capacity of 10 kA,
with phase-symmetrical current and maximum voltage of 480 V, with system-
side protection with RK 1 class, 600 V and maximum 200 A.
3.
Only UL-approved device connection cables (mains and DC cables) may be used:
− Use copper conductor with permissible temperature range +75 °C (+167 °F).
− For the tightening torques of the Power Supply Unit terminals see Table A.6,
− For the tightening torques of the choke terminals see Table A.14, p. 72
4.
The supplied chokes must be used.
5.
The devices are rated for installation in an environment of pollution severity 2 to
IEC/EN 60664-1.
A.13 Measures to attain UL approbation
(UL 508C) size 5
1.
Maximum temperature of ambient air: +40 °C (+104 °F) complete.
2.
The devices are usable in systems with a maximum current capacity of 5 kA
(G396-026) and 10 kA (G396-050), with phase-symmetrical current and
maximum voltage of 480 V, with system-side protection with RK 1 class, 600 V
and maximum 100 A.
3.
Only UL-approved device connection cables (mains and DC cables) may be used:
− Use copper conductor with permissible temperature range +60 - +75 °C
(+140 - +167 °F).
− For the tightening torques of the Power Supply Unit terminals see Table A.3,
− For the tightening torques of the choke terminals see Table A.14, p. 72
4.
The supplied chokes must be used.
5.
The devices are rated for installation in an environment of pollution severity 2 to
IEC/EN 60664-1.