Programmable Multi-Axis Servo Drive Power Supply Unit Operation Manual
ID no.: CA97556-001 Date: 03/2015
moog
67
Appendix
Size
Size 6A
Device
G396-075-xxx-xxx
G396-110-xxx-xxx
Mains supply voltage (±10 %)
400 V
AC
460 /
480 V
AC
400 V
AC
460 /
480 V
AC
Controlled DC link voltage
650 V
DC
770 V
DC
770 V
DC
650 V
DC
770 V
DC
770 V
DC
Input, mains side
Continuous current [A
AC eff
]
115
115
96
170
170
142
Peak current
1)
[A
AC
]
195
195
163
245
245
204
Switching frequency [kHz]
8
4
Continuous power [kVA]
80
118
Power loss
2)
[W]
2500
Asymmetry of mains voltage
±3 % maximum
Frequency
50/60 Hz
DC link output
Continuous current [A
DC
]
115
97
97
170
144
144
Peak current
1)
[A
DC
]
195
165
165
246
207
207
Continuous power [kW]
75
110
Peak power
1)
[kW]
127
160
DC link capacitance [µF]
4240
Internal fuse (X11)
125 A
200 A
Technical data applies to air-cooled and liquid-cooled housing variants
1) For 10 s
2) Approximation values
Table A.4 Size 6A technical data dependent on mains input voltage and controlled DC link
voltage
Size
Size 5
Device
G396-026
G396-050
X11/L+, L-
Screw size
M5
Use only the ready made-up cables supplied.
Tightening torque
2.5 ... 4.5 Nm (22 ... 39.8 lb-in)
X11/PE
Screw size
M5
Use only the ready made-up cables supplied.
Tightening torque
2.5 ... 4.5 Nm (22 ... 39.8 lb-in)
X12/L1,L2,L3
Cable connection capacity
0.5 ... 25 mm
2
(0.0008 … 0.04 in
2
)
(AWG 20...AWG 4)
1)
Tightening torque
2.5 ... 4.5 Nm (22 ... 39.8 lb-in)
X12/PE
Cable connection capacity
25 mm
2
2) 3)
(0.04 in
2
2) 3)
)
Tightening torque
2.5 ... 4.5 Nm (22 ... 39.8 lb-in)
X12/RB+, RB-
Cable connection capacity
0.5 ... 25 mm
2
(0.0008 … 0.04 inm
2
)
(AWG 20...AWG 4)
1)
Tightening torque
2.5 Nm (22 lb-in)
X12/ZK+, ZK-
Cable connection capacity
25 mm
2
(0.04 in
2
)
Tightening torque
2.5 ... 4.5 Nm (22 ... 39.8 lb-in)
1) Flexible cable with ferrule
2) Flexible cable with/without ferrule
3) The PE conductor cross-section depends on the cross-section of the outer conductor (see section 3.4, p. 33)
The minimum cross-section of the cables depends on the local regulations and conditions, as well as on the rated current
of the Power Supply Unit.
Table A.3 Connections