Commissioning
Example configuration of fieldbus address
In this example the fieldbus address is changed from 1 to 23.
Back
Back
T2
T2
T1 T2
T1 T2
Back
Apply
>5 s
>5 s
<5 s
<5 s
T1 T2
T1 T2
T1 T2
Value NOT
saved
Value
saved
T1
T2
T1
Tx
Tx
Press button Tx
(X = 1, 2) repeatedly
until desired menu
appears on display
Press button Tx
(X = 1, 2) once
Press button T1 and T2
simultaneously
Press any button
T1 T2
Figure 4.9 Example configuration of fieldbus address
NOTE:
y
During the flash phase after step 7 the save operation can be aborted by
pressing any button without the setting being applied. Otherwise the new
value is saved after five seconds.
y
The changed IP address is only applied once the control electronics have
been restarted (24 V reset).
4.4.5
Fieldbus address menu (Fb)
The functions available under this menu item depend on the device's communication
option. For detailed information refer to the relevant specification.
Menu level
Para-
meter
Value
range
Meaning
Explanation
1
2
Fb
Ad
-
00..xx
or
- -
Fieldbus
address
Setting of fieldbus address (only when fieldbus option
used), otherwise display "- -“
(The maximum programmable value depends on the
option)
Po
-
0..3
or
- -
Transmit
power
Setting of fibre-optic power output
(only with SERCOS II option), otherwise display "- -"
Table 4.10 Fieldbus address menu