Commissioning
]
Id no.: CA97555-001, Rev. 3.0 - Date: 06/2012
4 Commissioning
4.1 Notes for operation
ATTENTION!
•
Notes on safety
During operation pay attention to the notes on safety in chapter 1
•
During operation
Strictly avoid that ...
− foreign objects or moisture enters into the device
− aggressive or conductive substances are in the vicinity
− ventilation openings are covered
•
Cooling
− The device heats up during the operation and the temperature on the
heat may reach +100 °C (+212 °F). Danger of skin injury when touching.
− Cooling air must be able to flow through the device without restriction.
!
4.2 Initial commissioning
Once the MSD Servo Drive Compact has been installed as described in chapter 2 and
wired with all required voltage supplies and external components as described in
chapter 3, initial commissioning can performed in the following sequence:
Step
Action
Comment
1.
Installation and start of PC software
see Installation Manual
Moog
D
rive
A
DministrAtor
5
2.
Switching on control voltage
see section 4.2.1
3.
Connection between PC and drive
see section 4.2.2
4.
Parameter setting
see section 4.2.3
5.
Drive control with Moog
D
rive
A
DministrAtor
5
see section 4.2.4
NOTE:
Details concerning STO (Safe Torque Off) have not been taken into
account for initial commissioning, see chapter 6