moog
MSD Servo Drive Compact Operation Manual
9
[
Safety
]
Id no.: CA97555-001, Rev. 3.0 - Date: 06/2012
1 Safety
1.1 For your safety
The instructions set out below should be read through prior to initial commissioning
in order to prevent injury and/or damage to property. The safety instructions must be
followed at all times.
ATTENTION!
The MSD Servo Drive Compact‘s “Safe Torque Off (STO)” safety
function must be approved by the TÜV-Rheinland accredited certification
body. This certification is currently still in preparation. Conformance to parts
of EN ISO 13849-1, EN 62061, EN 61800-5-1 and EN 61508 is ensured.
!
1.1.1 Read the Operation Manual first!
1.
Read the Operation Manual first!
•
Follow the safety instructions!
•
Refer to the user information!
Electric drives are dangerous:
•
Electrical voltages of 230 V to 480 V
Dangerously high voltages of ≥ 50 V may still be present 10
minutes after the power is cut (capacitor charge). So check
that the power has been cut!
•
Rotating parts
•
Hot surfaces
Protection against magnetic and/or electromagnetic fields during installation
and operation.
•
Persons fitted with heart pacemakers, metallic implants and hearing aids
etc. must not be allowed access to the following areas:
− Areas where drive systems are installed, repaired and operated.
− Areas where motors are installed, repaired and operated. Motors with
permanent magnets pose a particular hazard.
NOTE:
If it is necessary to access such areas, suitability to do so must be
determined before hand by a doctor.
Your qualification:
•
In order to prevent personal injury or damage to property, only
personnel with electrical engineering qualifications may work on the
device.
•
The said qualified personnel must be familiar with the contents of the
Operation Manual (cf. IEC 364, DIN VDE 0100).
•
Awareness of national accident prevention regulations (e.g. BGV A3 in
Germany)
During installation observe the following instructions:
•
Always comply with the connection conditions and technical
specifications.
•
Comply with the standards for electrical installations, such as regarding
wire cross-section, grounding lead and ground connections.
•
Do not touch electronic components and contacts (electrostatic
discharge may destroy components).
Table 1.1 Safety instructions