© MOOG 2010
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
26
MRJ04410
Function Chart – Reference Terminal No’s 5-8, TB2
IN5
IN6
IN7
IN8
Direction
H
H
H
H
No Movement (Use Front Keys)
L
H
H
H
Move to Profile (F1) Mode
L
L
H
H
Move to Marker (F2) Mode
L
H
L
H
Move to File (F3) Mode
L
L
H
L
Move to Monitor (F4) Mode
L
H
H
L
Move to Data (F5) Mode
“H” is the condition for which the Photo Coupler is OFF. Changing form the Monitor (F4) Mode
to other Modes can only be done by using the function Keys on the front panel. The function
Keys on the front panel are disabled if IN5 is in condition (L).
TB-3: Power Supply
Term No.
Name
Specification
DC24V
Power Supply 24V
24V DC Input 0.5A min – 3.0A max
* Required install Fast blow Fuse.
* No ripple required, Max +-10 %
P GND
Power Supply 0V
0V for DC 24V
F GND
Earth
1-6-5.
NOISE AND GROUND ISOLATION
In any location there is always the potential for electrical noise interference and multiple ground paths.
Electrical noise can cause erratic system operation and is very difficult to find and isolate, ground loops
also cause unexpected operation as well as burn out components. In addition, mains voltage stability can
sometimes be questionable.
An isolation transformer between the mains and DigiPackⅡcan provide some relief from noise, ground
loops and wandering mains.
Figure 1-28 Power supply Connections