MRJ04410
Range H
Range H changes the value of all profile points by a percentage of
the difference between the thickness and thinnest points. The
value of the thinnest profile point remains constant during a
Range H change. Range H can vary between –100% and non limit +
side (3276.7%).
* If the profile over 100%, Range H still can be increase continu-
ously, however actual profile command is 100% maximum.
Use the Entry Knob and Set to change the Range H setting. The
percentage Range H change will remain displayed after being Set.
When the Entry Knob is turned again the new Range H entry will
start at zero using the current display as a reference. If the Entry
Knob is accidentally moved and the displayed Range H value
changed, it will revert to its former value if Set is not pressed and
the Cursor used.
Range H has the effect of allowing container weight changes
while retaining the containers minimum wall thickness distribution
pattern.
Figure 2-12
shows the effect of a Range H increase of +
32.8%
from the Range H value of 0% in
Figure 2-11
. To make the change
easier to visualize, reference lines drawn between the figures
starting at four different parison wall thickness program points
have been included.
Range H will use the thinnest parison wall thickness program
point as a reference and will not change its thickness. The
Range H change will be largest at the maximum parison wall
thickness point, and proportionately less at the intermediate
parison wall thickness poins.
Figure 2-12 (+)32.8% Range H Change
Figure 2-11 0% Range H