FULL__________________
The accumulator is now moved to its totally filled position, where it contains the maximum amount of
molten plastic. This is the Full position. The procedure is:
1)
“Die Gap” is activated
2)
The die gap tooling moves to 5% open
3)
Adjust the tooling opening if necessary
4)
Fill the accumulator with plastic
5)
Push SET at the Full position, the DigiPack
Ⅱwill store the Full position and turn on the
“End of Filling” LED
The Empty and Full value cannot set same value, it is automatically set 0.2V space, if set same
value e.g, Empty=5V and Full=5V, then automatically Empty set 4.8V.
And these two values can set only 0 to 10V. If set both 0V, value of “Full” change to 0.2V. And,
if set both 10V, value of “Empty” change to 9.8V automatically.
Pushing SET also select the Filling type to Extrusion/Filling
Extrusion_______
Plastic extrusion to the container
mold starts at the filled Accumulator
position determined by the sum of
Cushion, Shot size and Delay when
Filling type - Extrusion is selected.
End of extrusion is the Cushion po-
sition. “
Figure 1-45
” End of filling po-
sition is the Shot size stroke plus
Delay stroke plus the Cushion stroke.
Filling_________
Plastic extrusion to the container
mold starts at the Accumulator
filled position (End of Filling) when
FILLING FIXED is selected. The
length of stroke is determined by
the sum of SHOT SIZE plus DELAY.
(
Figure 1-46
)
Select either EXTRUSION FIXED or
FILLING FIXED and press SET.
Figure 1-45 Extrusion Fixed
Figure 1-46 Filling Fixed
Figure 1-44 FULL Accumulator Set Up