6.9.4.6 Object 0x5A00: 1st TxPDO mapping
First transmit PDO mapping.
With the parameter <LocalTPdo1_NumberOfMappedApplicParaInPdo> (0x5600) the number of real-time ap-
plication parameters to be transmitted can be set. To map the application parameter itself, its CANopen index,
sub-index and length must be combined to a 32 bit number and written to one of the eight possible positions
(corresponding to the sub-indexes 1…8) within the PDO object.
Chapter "2.8.3.5.1 Object 0x1A00: 1st TxPDO mapping", page 28
Value description
LocalCAN
Index
Sub-
index
Parameter name
Data
type
Access
Per-
sis-
tence
Value
range
Default
0x5A00
0
LocalTPdo1_NumberOfMappedApplicParaInPdo
UINT8
rw
Y
0…8
0
0x5A00
1
LocalTPdo1_ApplicPara1
UINT32
rw
Y
UINT32
0
0x5A00
2
LocalTPdo1_ApplicPara2
UINT32
rw
Y
UINT32
0
0x5A00
3
LocalTPdo1_ApplicPara3
UINT32
rw
Y
UINT32
0
0x5A00
4
LocalTPdo1_ApplicPara4
UINT32
rw
Y
UINT32
0
0x5A00
5
LocalTPdo1_ApplicPara5
UINT32
rw
Y
UINT32
0
0x5A00
6
LocalTPdo1_ApplicPara6
UINT32
rw
Y
UINT32
0
0x5A00
7
LocalTPdo1_ApplicPara7
UINT32
rw
Y
UINT32
0
0x5A00
8
LocalTPdo1_ApplicPara8
UINT32
rw
Y
UINT32
0
Parameter
Description
<LocalTPdo1_NumberOfMappedApplicParaInPdo>
Number of configured application objects
<LocalTPdo1_ApplicPara1>
Mapping of the 1
st
application parameter
<LocalTPdo1_ApplicPara2>
Mapping of the 2
nd
application parameter
<LocalTPdo1_ApplicPara3>
Mapping of the 3
rd
application parameter
<LocalTPdo1_ApplicPara4>
Mapping of the 4
th
application parameter
<LocalTPdo1_ApplicPara5>
Mapping of the 5
th
application parameter
<LocalTPdo1_ApplicPara6>
Mapping of the 6
th
application parameter
<LocalTPdo1_ApplicPara7>
Mapping of the 7
th
application parameter
<LocalTPdo1_ApplicPara8>
Mapping of the 8
th
application parameter
Table 64: Parameters of 1st TxPDO mapping object (0x5A00)
<LocalTPdo1_ApplicPara1…8>
Byte
3
2
1
0
Description
Index MSB
Index LSB
Sub-index
Parameter bit length 0x08,
0x10 or 0x20
Default
0x60
0x41
0x00
0x10