Moog ACV with CANopen bus interface
7 Servo valve functions
Monitoring
B99224-DV018-D-211, Rev. A, October 2018
244
7.15.8.1 Object 0x3217: Cable break monitoring analog input 2
If this parameter is set to 1 the cable break monitoring for the analog input 2 is enabled.
7.15.8.2 Object 0x3228: Cable break monitoring analog input 3
If this parameter is set to 1 the cable break monitoring for the analog input 3 is enabled.
7.15.8.3 Object 0x3227: Cable break monitoring analog input 4
If this parameter is set to 1 the cable break monitoring for the analog input 4 is enabled.
If the 0…10 mA or the ±10 mA analog input type is used, no sensor wire cable break monitoring is available.
In this case only the sensor power supply monitoring for the analog inputs 2…4 is active.
If the 4…20 mA analog input type is used, cable break monitoring for all analog inputs is available.
AnalogInput
Index
Sub-index
Parameter name
Data type
Access
Persistence
Value range
Default
0x3217
0
AnaInMonitorCurrent2
UINT8
rw
Y
0…1
0
AnalogInput
Index
Sub-index
Parameter name
Data type
Access
Persistence
Value range
Default
0x3228
0
AnaInMonitorCurrent3
UINT8
rw
Y
0…1
0
AnalogInput
Index
Sub-index
Parameter name
Data type
Access
Persistence
Value range
Default
0x3227
0
AnaInMonitorCurrent4
UINT8
rw
Y
0…1
0