Installation
Step 12:
Install the middle glass retainer.
Figure 98.
Step 13:
Install the outer most side. The outer glass barrier is secured
in place using a metal spring. See
Figure 95
. Be sure to butt the
glass forward to close the gap between the side and end.
Figure 99.
Glass installed (end view)
Note:
Removal of glass is the reverse of installation.
WARNING
Never use substitute materials. See
Replacing the Glass
for glass sizing and specifications.
WARNING
The outer glass barrier is a protective barrier. Operating the
appliance without this barrier could result in injury. Never
operate the appliance without all three layers of glass installed.
Figure 100.
Glass installed (side view - no gaps)
Step 14: