RP424PFC Indoor Gas Fireplace
Page 60
XG0781 - 151104
Maintenance
Replacing the Valve
Follow the steps below to service the valve.
Step 1:
Disconnect power and gas supply to the fireplace.
Step 2:
Remove glass barriers. See
Section 10
for installation and
removal of glass. Note: if removing glass from one side only, take
precautions against dirt and damage to the remaining sides.
Step 3:
Remove the access panel and inner valve cover. See
Accessing the Valve
.
Step 4:
Unplug electrical connectors from the valve.
Figure 124.
Step 5:
Using a 7/16" wrench, unscrew the pilot gas line from the valve.
Figure 125.
Step 6:
Using a 7/8" wrench, remove the flex lines from the gas
connections.
Note:
Replacement flex lines will come pre-assembled
with the replacement valve.
Figure 126.
Step 7:
Remove four screws securing the valve bracket to the valve
tray.
Figure 127.