Installation
Figure 19.
Step 2:
Remove the Inner Vent Cover.
Figure 20.
Step 3:
Remove the Pressure Tube using 1/2" wrench.
Figure 21.
Step 4:
Find the Rear Conversion Pressure Tube Kit located in the
Control Box.
Figure 22.
Step 5:
Attach the Rear Conversion Pressure Tube using 1/2"
wrench. Ensure the tube points straight out the rear of the appliance.
Figure 23.
Converting to Rear Vent
The
RP424PFC
can be easily converted from top vent to rear vent
by following the steps below.
Step 1:
Remove the Outer Vent Cover from the back of the fireplace.