RP424PFC Indoor Gas Fireplace
Page 51
XG0781 - 151104
Installation
Finish the fireplace as desired. Refer to
Section 3
for information
on finishing the fireplace.
Adjust the fan to optimal operation speed by performing the following
steps.
Step 1:
Turn the fireplace ON/OFF switch to the ON position and
wait 30 seconds for the power vent to power up.
Step 1:
Decrease the fan speed until the
Flue Gas Switch
LED
turns off.
Increase
speed
Decrease
speed
Figure 105.
Note:
Increasing the fan speed will result in cooler glass temperatures
if desired.
Adjusting the Fan Speed
The fan speed is set to full speed prior to shipment.
When lighting the fireplace the
Heat Sensor or Combustion Air
Switch
and
Wall Switch
LEDs will illuminate. After 30 seconds
when the power vent has reached operational speed the
Flue Gas
Switch
LED will also illuminate. Refer to
Section 8
.
Figure 104.
Step 2:
Slowly increase the fan speed in small increments until the
Flue Gas Switch