RP424PFC Indoor Gas Fireplace
Page 58
XG0781 - 151104
Maintenance
Replacing the Delay Timer
Follow the steps below to service the delay timer. See
Figure 36
for
a wiring diagram. When disconnecting each wire, we recommend
marking the wire to ensure they are reconnected in the correct
locations.
Step 1:
Disconnect power and gas supply to the fireplace.
Step 2:
Remove glass barriers. See
Section 10
for installation and
removal of glass. Note: if removing glass from one side only, take
precautions against dirt and damage to the remaining sides.
Step 3:
Remove the access panel and inner valve cover. See
Accessing the Valve
.
The delay timer is mounted above the valve on the left side of the
fireplace when viewed from the front.
If you need to replace the relays only:
Step 4:
Pull the relay from the receptacle.
Figure 119.
If you need to replace the Delay Timer Module:
Step 5:
Unplug the wires connected to the delay timer module. The
brown wire connects on the left side and the blue wire connects on
the right.
Step 6:
Remove the three screws securing the delay timer mounting
bracket.
Figure 120.
Figure 121.