The house batteries operate most of the interior lighting and appliances. As house battery power is
consumed, reserve battery capacity diminishes. The inverter can be programmed to automatically start
and stop the generator to keep up with the drain on the house batteries. All field reference points are
house battery indications or conditions. A wide field of parameters may be chosen for the genera-
tor start and stop points. These points may be set in three categories:
1. House battery voltage.
2. State of charge (SOC). The Fuel Gauge Cut-out affects SOC.
3. Absorb or Float point of the charge cycle.
Example:
The inverter can be programmed to start the generator when house battery voltage drops
and to stop the generator when the house battery voltage obtains a pre-programmed state of charge
(SOC). When selecting field reference points, the start and stop points spread to prevent short cycling
of the generator.
NOTE:
If the generator is started manually from any remote switch other than the RC7 GS
remote while the automatic generator start feature is enabled, the generator may shut
down due to field parameter settings.
To override the automatic generator operation and operate the generator manually, use the RC7
GS remote Inverter button. Press the
UP
or
DOWN
arrows while in the Main Menu until
Generator
Start/Stop: Press (ON/OFF)
is displayed. Manually stop the generator using the
ON/OFF
button.
Re-booting the Inverter
The RC7 GS remote is a display only. If the inverter exhibits unusual symptoms, such as not
responding to commands or displaying erroneous error conditions, re-boot the inverter.
To Re-boot the Inverter:
1. Remove AC power from the inverter by disconnecting shore power and/or shutting the
generator off.
2. Turn the main switch on the inverter to the
OFF
position.
3. Switch house and chassis main battery disconnects to the
OFF
position.
4. Wait 30 seconds, allowing time for the capacitors to discharge.
5. Switch house and chassis main battery disconnects to the
ON
position.
6. Turn the main switch on the inverter to the
ON
position.
7. Connect the shore power cord or start the generator.
Summary of Contents for Executive 2005
Page 14: ......
Page 16: ......
Page 30: ...Section 1 General Information The Executive 2005 30 NOTES...
Page 32: ......
Page 34: ......
Page 92: ...Section 2 Driving Safety The Executive 2005 92 Weight Label 100179D...
Page 98: ...Section 2 Driving Safety The Executive 2005 98 020254...
Page 101: ...Driving Safety Section 2 The Executive 2005 101 020263 WEIGHT RECORD SHEET 020262...
Page 102: ...Section 2 Driving Safety The Executive 2005 102 WEIGHT RECORD SHEET 020262...
Page 103: ...Driving Safety Section 2 The Executive 2005 103 010763d 010689d VIEWS Front Rear...
Page 104: ...Section 2 Driving Safety The Executive 2005 104 010687e 010688c Roadside Curbside...
Page 119: ...Driving Safety Section 2 The Executive 2005 119 NOTES...
Page 120: ...NOTES 120 The Executive 2005 Section 2 Driving Safety...
Page 122: ......
Page 132: ...Section 3 Exterior Interior Care The Executive 2005 132 Fabric Specifications Charts...
Page 133: ...Exterior Interior Care Section 3 The Executive 2005 133...
Page 134: ...Section 3 Exterior Interior Care The Executive 2005 134...
Page 135: ...Exterior Interior Care Section 3 The Executive 2005 135...
Page 136: ...Section 3 Exterior Interior Care The Executive 2005 136 Ralph Lauren Fabrics Optional Package...
Page 137: ...Exterior Interior Care Section 3 The Executive 2005 137...
Page 138: ...Section 3 Exterior Interior Care The Executive 2005 138...
Page 164: ...Section 3 Exterior Interior Care The Executive 2005 164 NOTES...
Page 166: ......
Page 204: ...Section 4 Appliances The Executive 2005 204 NOTES...
Page 206: ......
Page 264: ...Section 5 Equipment The Executive 2005 264 NOTES...
Page 266: ......
Page 299: ...Water Systems Section 6 The Executive 2005 299 TYPICAL WATER BAY 040496c...
Page 301: ...Water Systems Section 6 The Executive 2005 301 NOTES...
Page 302: ...Section 6 Water Systems The Executive 2005 302 NOTES...
Page 304: ......
Page 321: ...LP Gas Systems Section 7 The Executive 2005 321 NOTES...
Page 322: ...Section 7 LP Gas Systems The Executive 2005 322 NOTES...
Page 324: ......
Page 380: ...Section 8 Electrical Systems House The Executive 2005 380 Wiring Systems Interfaced...
Page 381: ...Electrical Systems House Section 8 The Executive 2005 381 NOTES...
Page 382: ...Section 8 Electrical Systems House The Executive 2005 382 NOTES...
Page 384: ......
Page 419: ...Electrical Systems Chassis Section 9 The Executive 2005 419 ENGINE NO START FLOW CHART...
Page 420: ...Section 9 Electrical Systems Chassis The Executive 2005 420 NOTES...
Page 422: ......
Page 523: ...Chassis Information Section 10 The Executive 2005 523 METRIC U S CONVERSION CHART...
Page 525: ...Chassis Information Section 10 The Executive 2005 525...
Page 526: ...Section 10 Chassis Information The Executive 2005 526...
Page 527: ...Chassis Information Section 10 The Executive 2005 527...
Page 529: ...The Executive 2005 Index...
Page 530: ......
Page 538: ...Index The Executive 2005 538 NOTES...