12
2 0 0 8 K n I G h t
water systems —
Check for an open or grounded circuit or
motor.
Check for a seized or locked diaphragm
assembly (water frozen).
Water pump will not prime or sputters
(No discharge/motor runs):
Is the pump inlet strainer clogged with
debris?
Is there water in the tank or has air
collected in the water heater?
Is the inlet tubing and plumbing sucking
in air at plumbing connections (vacuum
leak)?
Check for proper voltage with the pump
operating.
Check the pump housing for cracks or
loose drive assembly screws.
Water pump will not shut-off or continues
to run when the faucet is closed:
Check to see if the fresh water/tank fill
valve is completely closed.
Check the output (pressure) side
plumbing for leaks and inspect for a
leaky toilet or valves.
Look for a loose drive assembly or pump
head screws.
Water pump is noisy or rough in operation:
Check for plumbing that may have
vibrated loose.
Does the mounting surface multiply
noise (flexible)?
Check for mounting feet that are loose or
compressed too tight.
Look for loose pump head to motor
screws.
Water pump is rapid cycling:
Look for restrictive water flow in the
faucets or shower heads.
Water fIlter - faUcet
The filtration system filters up to 1,000 gallons
between filter changes. Depending on use
change filter cartridge approximately every 6
months (this is about 1,000 gallons) or when
water flow is noticeably reduced. The maximum
pressure for the system is 125 psi and maximum
temperature 100º F.
NOTE
Depending on floor plan, the water filter
can be located in several locations. One
location is an exterior compartment,
typically a curbside compartment.
Another location is behind the water
heater. To locate this water filter open
the compartment next to the water
heater. Once inside this compartment
open the access panel to gain entry to
the back of the water heater.
CAUTION
Protect filter from freezing or damage to
the system could occur.
Filter Removal:
Turn off the water
supply and the water
pump.
Open faucets to
bleed off pressure.
Unscrew the filter bowl using
the bowl wrench.
Check o-ring for damage and lubricate
if necessary. O-ring should be changed
every third cartridge change to ensure
proper sealing.
Remove the old cartridge and discard.
Empty any remaining water in the bowl.
Filter Installation:
Insert new cartridge into filter bowl.
Screw filter bowl back onto head and
hand tighten securely.
Turn on water pump or city water.
Thoroughly flush and purge air from the
system by opening faucets and running
the water for approximately 20 minutes.
Check for leaks.
To Winterize:
Disconnect the two
water line connections
(normal usage) on
either side of the filter
bowl head.
Connect a bypass hose
to the two water lines.
Unscrew the filter bowl
using the bowl wrench.
Remove the old
cartridge and discard.
Empty any remaining water in the bowl.
Store the filter bowl. DO NOT screw
filter bowl back onto filter head.
Winterize the motorhome.
To De-Winterize:
Disconnect the bypass hose to the two
water lines. Store bypass hose.
Reconnect the two water lines to the
filter bowl head.
040520c
Water Filter
Removal
Wrench
040520b
Summary of Contents for 2008 Knight
Page 12: ......
Page 14: ......
Page 16: ......
Page 46: ...driving safety 2 42 2008 Knight Weighing Procedure Worksheet Example Worksheet 020255b conv...
Page 47: ...2008 KNight 43 driving safety 2 Weight Record Sheet Actual Worksheet 020255b...
Page 52: ...driving safety 2 48 2008 Knight Notes...
Page 76: ...exterior interior care 3 72 2008 Knight Notes...
Page 190: ...electrical systems chassis 9 186 2008 Knight engine no start flow chart...
Page 233: ...2008 KNight chassis information 10 229 Notes...
Page 237: ...2008 KNight chassis information 10 233 Battery Specification Charts...
Page 246: ......