6.11 Slave Mode
Slave mode is an alternative to Manual mode and can be selected if one zone
has a faulty thermocouple. The slaved zone mimics the same power output
as the healthy zone, and, provided that they had been running at a similar
power level previously, the slaved zone will maintain a similar temperature.
1. Choose any zone to display the Command buttons.
2. Choose [
Set
].
3. Enter a password.
NOTE
Either the User or System password can be used.
4. Choose [
Slave
].
Enter the number of a healthy zone.
Choose [
Ent
].
5.
Return to the Main page to check that the first zone is now slaved to the
second selected zone.
The slaved zone will display the number of the zone to which it has been
slaved:
6-11
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
OPERATION
Me6 & Me12 Controller User Manual