6.22 QCIO - 4-Channel Input / Output Card
The digital Input / Output card offers up to four separate inputs and outputs to
facilitate remote interaction with the controller.
Setup is available on the Utilities page.
Choose [
QuadIO
] to see the input and output selection.
6.22.1 Inputs
Each input circuit requires an incoming pair that is volt-free and normally
open. The incoming pair must go to short circuit (or close) to trigger the
required command.
Optional inputs that may be selected are as follows:
Table 6-7 Quad IO Inputs
Option
Description
Boost
Puts the Controller into BOOST mode.
Inactive
This input will not be used and remains inactive.
Machine OK
When closed, console can go to RUN mode or STARTUP
mode.
When opened, the console is put into STOP mode with
Mold Protect.
Passkey
Responds to an external cardkey reader, which is used to
simulate User level authentication.
A passkey input then allows any operation which would
normally require a User / Level 1 password.
Run
Puts the Controller into RUN mode.
Shutdown
Puts the Controller into SHUTDOWN mode.
Standby
Puts the Controller into STANDBY mode.
Startup
Puts the Controller into STARTUP mode.
Stop
Puts the Controller into STOP mode.
6-30
M1 Plus Controller User Manual
OPERATION
© 2021 Mold-Masters (2007) Limited. All Rights Reserved.